ul design no. w413

QUIETZONE APPLICABLE CODES AND STANDARDS ACOUSTICAL BATT INSULATION TABLE 41 Double Wood Stud Wall 3-12 With 1 min Air Space in Between 2 Layers Spacing for 2 rows of 3 12 Wood Studs 16 or 24 oc. See Items 1 1A 2 2A and 6 Bearing Wall Rating 12 HR.


2

W411 June 06 2013 Nonbearing Wall Ratings 12 or 1 HR.

. Ul design no. Only products which bear ULs Mark are considered Certified. These two assemblies known as UL W404 and UL W413 contain several prominent attributes.

It became apparent that a special gypsum wall-board fire protection framing design was needed to take advantage of the existing components used in metal buildings. W404 for new and retrofit metal buildingsprovides the required flexibility to meet future energy code requirements for higher insulation levels. UL Design V421 GYPSUM WALLBOARD RIGID FURRING CHANNELS STEEL GIRTS STEEL WALL PANELS EXTERIOR SIDE.

16 or 24 oc. 2 formerly Insurance Bulletin 16 which are based on UL Design Nos. U 4 1 1 July 31 2021 Nonbear ing Wall Rating 2 Hr.

The new two hour rated wall test UL Design No. 5 Be sure you understand building classifications. For jurisdictions employing the Limit States Design Method such as Canada a load restriction factor shall be used.

U489 and U425 were adapted for use in MBMA buildings where fire resistance ratings were needed. Two fire-resistance rated wall assemblies were successfully developed and tested at Underwriters Laboratories Inc. 20 MSG 76mm wide 38mm deep min spaced 610mm oc.

One testthe one hour UL Design No. 12-14 self-drilling screws 12 oc. This design was evaluated using a load design method other than the Limit States Design Method eg Working Stress Design.

D e s i g n N o. Perpendicular to girts 102mm thick min mineral fiber batts 64 kgm3 min density 89mm thick min R-10 glass fiber blankets attached to horizontal girts. Fire-resistance Ratings - ANSIUL 263 See General Information for Fire-resistance Ratings - ANSIUL 263 Design No.

Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification such as Canada respectively. W411 June 06 2013 Nonbearing Wall Ratings 12 or 1 HR. 16 or 24 oc.

Finish Rating Min 20 min. They impact insurance rates. Indicat es such pr oducts shall bear the UL or cUL Cer tification Mark for jur isdictions employing the UL or cUL Cer tification such as Canada r espectively.

See Items 3 and 6 Finish Rating See Item 3. W413 is similar to W404 but it includes additional materials to meet the more stringent rating. W419 May 27 2015 Nonbearing Wall Rating 1 2 3 or 4 Hr.

W413 Written By vukelj Wednesday March 23 2022 Add Comment Edit UL Design No W4132 3 layers of 159mm thick Type X Gypsum Board Furring channels No. Floor and Ceiling Runner. With 1-12 long No.

W413 May 26 2015 Non Load Bearing Wall Rating 2 Hr. U341 September 23 2020 Bearing Wall Rating 1 Hr. See General Information for Fire-resistance Ratings - ANSIUL 263 See General Information for Fire Resistance Ratings - CANULC-S101 Certified for Canada Design No.

Minimum 26 gage steel exterior wall panels applied at right angles to horizontal 6 to 12 deep Z or C shaped 0056 to 0120 thick steel girts 48 oc. Design Criteria and Allowable Variances. Both designs preserve the most.

This design was evaluated using a load design method other than the Limit States Design Method eg Working Stress Design Method. UL Design No W4132 3 layers of 159mm thick Type X Gypsum Board Furring channels No.


2


Fire Resistance Bulletin 5 Metal Building Manufacturers Association


2


Fire Resistance Bulletin 5 Metal Building Manufacturers Association


Ul Design U415


2


Fire Resistance Bulletin 5 Metal Building Manufacturers Association


Fire Resistant Assemblies Sa 100 Cgc